{"product_id":"trilite-bwule-4040","title":"TRILITE BWULE-4040","description":"\u003c!--description--\u003e\n\u003cdiv\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cb\u003eTRILITE BWULE-4040, \u003c\/b\u003e\u003cb\u003eUltr\u003c\/b\u003e\u003cb\u003e Low \u003c\/b\u003e\u003cb\u003ePressure\u003c\/b\u003e\u003cb\u003e Reverse Osmosis Membrane\u003c\/b\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"w5tmo\" data-start=\"81\" data-end=\"157\"\u003eLow operating pressure (approximately half of standard RO membranes)\u003c\/li\u003e\n\u003cli data-section-id=\"1tw21vv\" data-start=\"158\" data-end=\"192\"\u003eReduced energy consumption\u003c\/li\u003e\n\u003cli data-section-id=\"1krd8p\" data-start=\"193\" data-end=\"281\"\u003eLower initial system cost (smaller pumps, piping, valves, and related equipment)\u003c\/li\u003e\n\u003cli data-section-id=\"1ei7weg\" data-start=\"282\" data-end=\"334\"\u003eSuitable for feed water with \u003cstrong\u003eTDS \u0026lt; 1,000 ppm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"s5exzk\" data-start=\"335\" data-end=\"438\"\u003eApplications: Drinking water, low-salinity industrial water, food and pharmaceutical industries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 99.915%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.1209%; text-align: center;\"\u003e \u003cspan\u003ePermeate Flow GPD (m\u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\u003cspan\u003e\/d)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.1209%; text-align: center;\"\u003e\u003cspan\u003eStable Rejection Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 32.9409%; text-align: center;\"\u003e\u003cspan\u003eOperating pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.1209%; text-align: center;\"\u003e2,600 (9.8)\u003c\/td\u003e\n\u003ctd style=\"width: 33.1209%; text-align: center;\"\u003e99.2 %\u003c\/td\u003e\n\u003ctd style=\"width: 32.9409%; text-align: center;\"\u003e\u003cspan\u003e100 psi (690 kpa)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp data-pm-slice=\"0 0 []\"\u003e\u003cstrong\u003eTest Conditions: \u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli data-pm-slice=\"0 0 []\"\u003e Operating Pressure 100psi (0.69Mpa \/ 7.03kgf\/cm2)\u003c\/li\u003e\n\u003cli data-pm-slice=\"0 0 []\"\u003eTemperature 25℃ (77℉)\u003c\/li\u003e\n\u003cli data-pm-slice=\"0 0 []\"\u003eTested at 500mg\/L NaCl Solution.\u003c\/li\u003e\n\u003cli data-pm-slice=\"0 0 []\"\u003epH 6.5~7.5 5.\u003c\/li\u003e\n\u003cli data-pm-slice=\"0 0 []\"\u003eRecovery Rate at 15%. \u003c\/li\u003e\n\u003cli data-pm-slice=\"0 0 []\"\u003eEach membrane element may have ±20% variation of permeate flow rate\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan\u003e* Pre-treatment must be used to protect the membrane (softener, antiscalant dosing pump, sand filter, carbon filter, 5 mic cartridge fitler ...etc).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for Low Salinity Inlet Water to Operate at Ultra Low Pressure (6.9 bar \/ 100 PSI)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!--tab_content--\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003eProduct Specifications:\u003c\/strong\u003e\u003cbr\u003eSalt Rejection: 99.2%*\u003cbr\u003ePermeate Flow: 2,600 gpd (9.8 m³\/day)*\u003cbr\u003eMembrane Area: 100 ft².\u003cbr\u003eDiameter 4 inch \/ Length 40 inch.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan\u003eTRILITE BWULE-4040 reverse osmosi membrane is suitable for water purification applications of water sources with salt concentration \u003cstrong\u003elower than 1000 ppm\u003c\/strong\u003e, such as surface water, underground water, tap water and municipal water.\u003cbr\u003eULE \/ ULP series of membrane element is particularly applicable to the second-pass desalination with two-pass RO system.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003eCommercial Application:\u003c\/strong\u003e\u003cbr\u003e- Drinking water.\u003cbr\u003e- Softened water for homes, hotels, commercial laundries and car wash.\u003cbr\u003e- Spot free rinse like window cleaning and solar panel cleaning\u003cbr\u003e- Pure water for pharmaceuticals, laboratories, Hemodialysis and electronics\u003cbr\u003e- Sterilisers and autoclaves.\u003cbr\u003e- Chemical industry.\u003cbr\u003e- Aquarium water treatment.\u003cbr\u003e- Boiler and cooling towers make-up water.\u003cbr\u003e- Pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production..\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003eCompatible with reverse osmosis membrane types:*\u003c\/strong\u003e\u003cbr\u003eDow Filmtec XLE-4040 , LG BW 4040 UES, Vontron XLP11-4040, Toray TMG10 , CSM RE4040-BLF , GE AK4040FM , GE AK-90.\u003cbr\u003e*Check the data sheet for each membrane.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0665\/3463\/7724\/files\/EN_TDS_TRLITE_BWULE-4040.pdf?v=1774486976\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eDownload Trilite BWULE-4040 Data Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp data-end=\"103\" data-start=\"54\"\u003e\u003cstrong data-end=\"67\" data-start=\"54\"\u003eReplaces:\u003c\/strong\u003e Vontron XLP11-4040, LG BW 4040 UES\u003c\/p\u003e\n\u003cp data-end=\"158\" data-start=\"105\"\u003e\u003cstrong data-end=\"125\" data-start=\"105\"\u003eManufactured by:\u003c\/strong\u003e Samyang (Korea), Made in China\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003eOperation Conditions:\u003c\/strong\u003e\u003cbr\u003eMax. working pressure:  600 psi (4.14MPa)\u003cbr\u003eMax. Feed water flow:  16 gpm (3.6 m3\/h)\u003cbr\u003eMax. Temperature of Feed water:  45℃\u003cbr\u003eMax. Feed water SDI15: 5.\u003cbr\u003eMax. Feed Water Total Hardness: 10 ppm (softener or antiscalant should be used).\u003cbr\u003epH Range of Feed water during Continuous Operation:  3～10\u003cbr\u003epH Range of Feed Water during Chemical Cleaning:  2～12\u003cbr\u003eResidual chlorine Concentration of feed water ＜0.1ppm Max.\u003cbr\u003ePressure drop of single membrane element:  15psi (0.1MPa)\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"MDC Water","offers":[{"title":"Default Title","offer_id":46591635095708,"sku":"TRILITE BWULE-4040","price":325.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/3463\/7724\/files\/TRILITE_4040_RO_Membrane_Australia.jpg?v=1775522629","url":"https:\/\/waterfilter.net.au\/products\/trilite-bwule-4040","provider":"MDC Water ","version":"1.0","type":"link"}