Hi Flow 4040 Seawater RO Membrane, Vontron SW4040LE

4”x40” Sea Water Membrane

1,900 gpd / 99.7% / 800 PSI

Provides high productivity and high salt rejection.

 

SW sea water membranes provide optimum salt rejection and permeate flows. They are chosen when higher flow product water and lower feed pressures are needed.

Brief Introduction SW series of sea water aromatic polyamide RO element developed by VONTRON for seawater desalination. This series of elements have the characteristics of low operating pressure, low equipment investment, good desalination performance and stability. Among them, the SW8040XHR-400 have the highest desalination rate of 99.85%, which ensure that drinking water can be produced from seawater through one pass RO system.

 

Specified Performance*:

Salt Rejection: 99.7%.
Permeate Flow: 1,900 gpd (7.2 m³/day).
Membrane Area: 90 ft².
Diameter/Length: 4 inch / 40 inch.
Feed Spacer Thickness: 28 mil.
Test conditions: 32,000 mg/l NaCl, 55.2 bar (800 psi), 25 °C (77 °F), pH 8, recovery rate 8%.
*The Specified Performance is based on data taken after approximately 30 minutes of operation. Actual testing of elements may be done at conditions which vary from these exact values; in which case, the performance is normalized back to these standard conditions. Permeate flow for individual elements may vary +25 / -15 percent from the value specified.

Application:

Vonron SW4040LE is a standard size seawater membrane, widely used for watermakers, desalinators, seawater desalination systems, marine (yacht and boat), Navy and martime applications.
Commonly used in on-board Watermakers to create drinking water from seawater for yachts, boats, and cruise ships.

Made in China by Vontron

Equivalent to*:
Filmetc SW30-4040, GE Desal SE4040FF, Hydranautics SWC5-LD-4040, Hydranautics SWC1-4040 , Toray TM-810L , CSM RE4040-SHA.
*Check the data sheet for each membrane.

Download:
Technical Data Sheet

Discover more in our FAQ

What types of industrial water treatment products do you offer?

How do I know which product is right for my application?

Do you offer bulk pricing for large industrial orders?

How long does shipping take?

What is your return policy?

What happens if I receive a damaged or incorrect item?

How long does shipping take?

Do you ship internationally?

Recently Viewed Products

FilmTec XLE PRO 4040 Membrane, 4 inch x 40 inch Reverse Osmosis Membrane

  • Extra Low Energy Tape-Wrapped Membrane.
  • High flux (productivity) results in high yields.
  • Flow 2,750 gpd / Salt Rej 99% / Pressure 125 PSI.

FilmTec™ XLE PRO-4040 Elements offer better system performance and economics for small commercial systems by operating at very low applied pressure.

FilmTec XLE PRO-4040 elements are tape-wrapped. In addition to high-quality water and low energy costs, FilmTec membranes also deliver savings by providing long lasting and reliable performance. For added convenience, the elements are available in a dry state for rapid start-up.

High productivity membrane, it produces good water quality at very low applied pressure for drinking water and commercial applications.

Replaces Filmtec XLE-4040 (old version).

 

Specified Performance*:

Manufacturer Part Number: 12082995
Model Number: XLE PRO 4040
Permeate Flow: 2,750 gpd (10.4 m3 /d).
Stabilised Salt Rejection: 99%.
Nominal Active Surface Area: 87 ft².
Diameter: 4" (99mm)
Length: 40" (1016mm)
Membrane Type: Polyamide Thin-Film Composite. 

*1. Permeate flow and salt rejection based on the following test conditions: 2,000 ppm NaCl and 125psig (8.7 bar) , pH8, 77°F (25°C) and 15% recovery.
2. Minimum salt rejectionis 97%.
3. Permeate flows for individual elements may vary +/-15%.

XLE 4040 Specifications

Max. Feed Flow Rate: 3.2m³/hr
Max. Operating Pressure: 41bar
Max. Operating Temperature: 45°C
Max. Pressure Drop: 0.9 bar
pH. Range (Continuous Cleaning): 2 - 11
pH. Range (Short-Term Cleaning): 1 - 13
Maximum Feed Silt Density Index: SDI 5
Free Chlorine Tolerance: <0.1ppm
Manufactured by DuPont

 

 

DuPont RO Membranes

FilmTec™ Brackish Water Reverse Osmosis 4" Elements can separate salts from water and are produced with an automated fabrication process that ensures precision, consistency, and reliability. They are ideal for use in medium-sized water treatment system that produce less than approximately 10 gpm (2300 L/h) of permeate. DuPont Reverse Osmosis membranes build on a tradition of leadership in the thin-film composite membrane industry and meet the challenges of higher rejection in lower-pressure operations.

Commercial Application:

- Demineralisation for industrial applications, such as: PowerGeneration, Steel & Metal, Chemical & Petrochemical
- Drinking water.
- Softened water for homes, hotels, commercial laundries and car wash.
- Spot free rinse for window cleaning and solar panel cleaning
- Pure water for pharmaceuticals, laboratories, Hemodialysis and electronics
- Sterilisers and autoclaves.
- Chemical industry.
- Aquarium water treatment.
- Boiler and cooling towers make-up water.
- Pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production.

 

Download:
Filmtec XLE PRO-4040 Data Sheet

General Information:
- Keep elements moist at all times after initial wetting.
For successful operation of Reverse Osmosis (RO) and Nanofiltration (NF) membrane systems, the operation must follow the guidelines provided in the FilmTec™ ReverseOsmosis / Nanofiltration Elements Operation Excellence and Limiting Conditions Tech Fact (Form No. 45-D04388-en).
- To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.
- The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.
- Avoid static permeate-side back pressure at all times.
- Permeate obtained from the first hour of operation should be discarded.
- The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system.

Important Information:
- Proper start-up of reverse osmosis water treatment systems isessential to prepare the membranes for operating service  and to prevent membrane damage due to over feeding or hydraulic shock. Following the proper start-up sequence also  helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved..
- Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.

Product tabs

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Collapsible tab heading

Collapsible tab heading

Product bundles

Product bundles