Reverse Osmosis (RO) Membranes

Type the code on your old element. We will show you what fits.

Elements here come in five size codes: 2521, 2540, 4021, 4040 and 8040. Size codes are nominal: a 4040 is a nominal 4 inch element, 40 inches long. The grades are seawater, brackish water and low pressure, from CSM, FilmTec (DuPont), Hydranautics, Trilite, Vontron and NanoH2O Co., Ltd. Each grade is rated on a different test: seawater elements on 32,000 ppm NaCl at 800 psi, brackish elements on 1,500 to 2,000 ppm NaCl at 225 psi, and low pressure elements at 100 to 150 psi on 500 to 2,000 ppm NaCl. Those are the makers' test pressures, not their maximum operating pressures, so compare each model on its product page.

e.g. BW30-4040 or SW30-2540. Type it as printed on the element. Spaces and dashes do not matter.
Size

Brands listed: CSM - Toray, FilmTec - DuPont, Hydranautics, LG - NanoH2O, Trilite, Vontron.

28 of 28 shown. 20 in stock.

Buy replacement RO membranes in Australia

Shop replacement reverse osmosis membranes in Australia for commercial, industrial, marine and water treatment systems. Find seawater, brackish water and low pressure RO elements in 2521, 2540, 4021, 4040 and 8040 sizes from CSM-Toray, FilmTec, Hydranautics, LG NanoH2O, Vontron and more

Ordering 5 or more? Call or chat for trade pricing.

Seawater, brackish or low pressure?

Test basis from the maker datasheets we hold. Each product page shows its own figures.

Seawater

800 psiTest pressure

Rated on 32,000 ppm salt water.

252125404040
See seawater membranes

Brackish

225 psiTest pressure

Rated at 1,500–2,000 ppm salinity.

40408040
See brackish membranes

Low pressure

100 to 150 psiTest pressure

Rated at a lower test pressure with feedwater salinity of 500–2,000 ppm.

2521 to 8040
See low pressure membranes

Match your existing RO membrane

Each maker's own length and outside diameter are in the spec table on its product page. Flow, rated rejection and pressure differ by model, so compare the figures on each product page.

Reading a size code

4040 is a nominal 4 inch element, 40 inches long.

2521 and 2540 elements are made for a nominal 2.5 inch vessel, 4021 and 4040 for a nominal 4 inch vessel, and the 8040 for a nominal 8 inch vessel.

CodeNominalActual element (length x outside diameter)Maker sheets say it fits
2521nominal 2.5 x 21 in533 x 61 mm (21.0 x 2.4 in)FilmTec SW30 sheet (Form 45-D01519-en Rev 10): nominal 2.5 inch vessel
2540nominal 2.5 x 40 in1,016 x 61 mm (40.0 x 2.4 in)FilmTec SW30 sheet (Form 45-D01519-en Rev 10): nominal 2.5 inch vessel
4021nominal 4 x 21 in533 x 99 mm (21 x 3.9 in)FilmTec SW30 sheet (Form 45-D01519-en Rev 10): nominal 4 inch vessel
4040nominal 4 x 40 in1,016 x 99 to 100.3 mm (40.0 x 3.9 to 3.95 in), by makerFilmTec and CSM sheets: nominal 4 inch vessel
8040nominal 8 x 40 in1,016 x 200 to 201 mm (40.0 x 7.9 in)FilmTec BW30-400 sheet (Form 45-D01505-en Rev 4): nominal 8 inch vessel We do not list an 8 inch vessel. Ask us.

Find a replacement RO membrane

Type or pick another maker's model

We will check what fits. Send us the code.

  • DuPont's sheet gives the FilmTec BW30 PRO-4040 higher rejection and flow than the previous generation FilmTec BW30.
  • Earlier datasheets list the BW 4040 R, BW 4040 ES and BW 400 ES as LG models; the current datasheets (v260930) are issued by NanoH2O Co., Ltd.

Replacing the vessel too?

Check the vessel's design pressure against your system before you order.

See all vessels
ImageVesselFor elementsDesign pressurePriceView
2.5 x 21 in FRP vesselMembrane pressure vessel Size2521 Design pressure1,000 psi (7.0 MPa) from $395.00 View
2.5 x 40 in FRP vesselMembrane pressure vessel Size2540 Design pressure1,000 psi (7.0 MPa) from $465.00 View
4 x 21 in FRP vesselMembrane pressure vessel Size4021 Design pressure300 psi (2.1 MPa) from $295.00 View
4 x 40 in FRP vesselMembrane pressure vessel Size4040 Design pressure300 psi (2.1 MPa) from $339.00 View
4 x 40 in FRP housingMembrane pressure vessel Size4040 Design pressure1,000 psi (7.0 MPa) from $980.00 View
8040 elements We do not list an 8 inch vessel. Ask us.
1812 to 2812 elements Not listed here.

Datasheets by model

Figures last checked 3 Nov 2026.
CSM - Toray
CSM RE4040-BE Brackish RO Membrane, 4040 (nominal 4 x 40 in) CSM RE4040-BE datasheet PDF
CSM RE4040-BLN Low Pressure RO Membrane, 4040 (nominal 4 x 40 in) CSM RE4040-BLN datasheet PDF
CSM RE4040-FEn Brackish RO Membrane, 4040 (nominal 4 x 40 in) CSM RE4040-FEn datasheet PDF
FilmTec - DuPont
FilmTec SW30-2540 Seawater RO Membrane, 2540 (nominal 2.5 x 40 in) FilmTec SW30-2540 datasheet (DuPont) PDF
FilmTec BW30 PRO-4040 Brackish RO Membrane, 4040 (nominal 4 x 40 in) FilmTec BW30 PRO-4040 datasheet (DuPont), Form 45-D03970-en Rev 5, Oct 2024 PDF
FilmTec SW30-2521 Seawater RO Membrane, 2521 (nominal 2.5 x 21 in) FilmTec SW30-2521 datasheet (DuPont) PDF
FilmTec BW30-400 Brackish RO Membrane, 8040 (nominal 8 x 40 in)
Hydranautics
Hydranautics CPA5-LD-4040 Brackish RO Membrane, 4040 (nominal 4 x 40 in) Hydranautics CPA5-LD-4040 datasheet (Hydranautics), dated 25 Sep 2023 PDF
Hydranautics SWC5-LD-4040 Seawater RO Membrane, 4040 (nominal 4 x 40 in) Hydranautics SWC5-LD-4040 datasheet (Hydranautics), dated 5 Mar 2021 PDF
Hydranautics CPA5-LD Brackish RO Membrane, 8040 (nominal 8 x 40 in) Hydranautics CPA5-LD (8040) datasheet (Hydranautics), dated 14 May 2025 PDF
LG - NanoH2O
LG BW 4040 R Brackish RO Membrane, 4040 (nominal 4 x 40 in) LG BW 4040 R datasheet (NanoH2O), v260930 PDF
LG BW 4040 ES Low Pressure RO Membrane, 4040 (nominal 4 x 40 in) LG BW 4040 ES datasheet (NanoH2O), v260930 PDF
LG BW 400 ES Low Pressure RO Membrane, 8040 (nominal 8 x 40 in) LG BW 400 ES datasheet (NanoH2O), v260930 PDF
Trilite
Trilite BWHR-4040 Brackish RO Membrane, 4040 (nominal 4 x 40 in) Trilite BWHR-4040 datasheet (PDF) PDF
Trilite BWLE-4040 Low Pressure RO Membrane, 4040 (nominal 4 x 40 in) Trilite BWLE-4040 datasheet (PDF) PDF
Trilite BWULE-4040 Ultra Low Pressure RO Membrane, 4040 (nominal 4 x 40 in) Trilite BWULE-4040 datasheet (PDF) PDF
Vontron
Vontron ULP21-4040 Low Pressure RO Membrane, 4040 (nominal 4 x 40 in) Vontron ULP21-4040 datasheet (PDF, Vontron) PDF
Vontron LP21-4040 Brackish RO Membrane, 4040 (nominal 4 x 40 in) Vontron LP21-4040 datasheet (PDF, Vontron) PDF
Vontron ULP31-4040 Low Pressure RO Membrane, 4040 (nominal 4 x 40 in) Vontron ULP31-4040 datasheet (PDF, Vontron) PDF
Vontron XLP11-4040 Ultra Low Pressure RO Membrane, 4040 (nominal 4 x 40 in) Vontron XLP11-4040 datasheet (Vontron XLP series page) WEB
Vontron ULP11-4040 Low Pressure RO Membrane, 4040 (nominal 4 x 40 in) Vontron ULP11-4040 Datasheet (Vontron sheet, PDF dated August 2017) PDF
Vontron SW11-2540 Seawater RO Membrane, 2540 (nominal 2.5 x 40 in) Vontron SW11-2540 datasheet (Vontron seawater series page) WEB
Vontron ULP21-4021 Low Pressure RO Membrane, 4021 (nominal 4 x 21 in) Vontron ULP21-4021 datasheet PDF
Vontron SW11-2521 Seawater RO Membrane, 2521 (nominal 2.5 x 21 in) Vontron SW11-2521 datasheet (Vontron seawater series page) WEB
Vontron ULP21-2521 Low Pressure RO Membrane, 2521 (nominal 2.5 x 21 in) Vontron ULP21-2521 datasheet (Vontron ULP series page) WEB
Vontron SW4040LE Seawater RO Membrane, 4040 (nominal 4 x 40 in) Vontron SW4040LE datasheet (PDF, Vontron) PDF
Vontron ULP21-2540 Low Pressure RO Membrane, 2540 (nominal 2.5 x 40 in) Vontron ULP21-2540 datasheet (PDF, Vontron) PDF
Vontron ULP22-8040 Low Pressure RO Membrane, 8040 (nominal 8 x 40 in) Vontron ULP22-8040 datasheet (PDF, Vontron) PDF

Who we supply and how it ships

We supply defence, government, industrial and water treatment customers across Australia and internationally.

Since 1998MDC Water
Trade & Bulk PricingCompetitive rates for volume orders
Next business dayDispatch on in-stock items
Remote sitesFreight Australia-wide
The membranes were dispatched promptly, were well packaged, and arrived in perfect condition.
MDC Water customer review
Great service, prompt answering of questions and quick shipment
MDC Water customer review

Frequently asked questions

What is an RO membrane element?

An RO element is the membrane that sits inside a pressure vessel in a reverse osmosis system. Elements are named by the maker's model code (for example BW30 PRO-4040) and a size code (4040).

What does a size code like 4040 mean on an RO membrane?

4040 is a nominal 4 inch element, 40 inches long. The first two digits are the nominal diameter in tenths of an inch (40 is 4.0) and the last two are the length in inches. So 8040 is nominal 8 inch, 40 inches long; 2540 is nominal 2.5 inch, 40 inches long; 2521 is nominal 2.5 inch, 21 inches long; 4021 is nominal 4 inch, 21 inches long. Per FilmTec's datasheets, 2521 and 2540 elements are made for a nominal 2.5 inch vessel, 4021 and 4040 for a nominal 4 inch vessel, and the BW30-400 for a nominal 8 inch vessel; CSM's RE4040 datasheets say the same for the 4040.

What is the difference between a 4040 and a 4021 membrane?

Both are nominal 4 inch elements. A 4021 is 21 inches long and a 4040 is 40 inches long (533 mm and 1,016 mm on the maker sheets), so they do not interchange. Per FilmTec's datasheets, both are made for a nominal 4 inch vessel; our 4 inch FRP vessels come in two lengths, the 4x21 for one 4021 element and the 4x40 for one 4040 element.

What size is an 8040 membrane, and what vessel does it go in?

An 8040 is a nominal 8 inch element, 40 inches long; the maker sheets give 1,016 mm long and 200 to 201 mm outside diameter. FilmTec's datasheet says its BW30-400 is made for a nominal 8 inch vessel. We do not list an 8 inch vessel. Ask us.

How do I find the size of the RO membrane I need to replace?

Read the code printed on the element you are replacing, for example SW30-2540 or BW 4040 R. The four digits are the size: 25, 40 or 80 is the nominal diameter (2.5, 4 or 8 inches) and 21 or 40 is the length in inches. Type the code into the box at the top of this page, or send it to us and we will check what fits.

Can I swap one brand of 4040 membrane for another?

Match the model code of the element you are replacing. Flow, rated rejection and pressure differ by model, so compare the figures on each product page. Send us the model number. We will check what fits.

What is the difference between low pressure, brackish and seawater membranes?

The grades differ by test basis. On the maker datasheets we hold, seawater elements are rated on 32,000 ppm NaCl at 800 psi (FilmTec SW30, Hydranautics SWC5-LD, Vontron SW4040LE), brackish elements on 1,500 to 2,000 ppm NaCl at 225 psi, and low pressure elements (also sold as ULP or XLP) at a lower test pressure, 100 to 150 psi, on 500 to 2,000 ppm NaCl. See each product page for the maker's figures.

Who does MDC Water supply?

We supply defence, government and universities, across Australia and overseas. Every order comes with a tax invoice. MDC Water, since 1998.

Do you have RO membranes in stock in Australia?

Stock is shown live on every product page. In-stock items dispatch next business day. Tax invoice on every order. Freight to remote sites Australia-wide. Ordering 5 or more? Call or chat for trade pricing.

Can you help me choose a membrane?

Send us the model number on your element, or its size code. We will check what fits. Call or chat.

How often should an RO membrane be replaced?

DuPont's FilmTec technical manual says FilmTec 2.5 and 4 inch elements in light industrial systems built to its Table 23 guidelines have an expected membrane lifetime of more than 3 years. For the same elements in small commercial systems built to its Table 24 guidelines, typically 1 to 6 elements either regularly replaced or cleaned (every half year or year) or where performance loss is acceptable, DuPont's manual says the expected element lifetime is not more than 3 years. In systems that control scaling by preventive cleaning, mainly small single-element plants for potable water from tap water or seawater, DuPont's manual says the elements are replaced after 1 to 2 years. For your own element, check its maker's documents.

How do you know an RO membrane needs replacing?

DuPont's FilmTec technical manual says high salt passage with higher than normal permeate flow in a FilmTec element is mostly due to oxidation damage, from free chlorine, bromine, ozone or other oxidising chemicals, and that no corrective action is possible: all damaged elements must be replaced. DuPont's manual also says to replace FilmTec elements damaged by telescoping, and correct the causes, or by surface abrasion. DuPont's FilmTec cleaning procedures excerpt says permeate flux drops when feedwater temperature decreases, and that this is normal and does not indicate membrane fouling. For your own element, see its maker's guidance.

Should you clean an RO membrane or replace it?

DuPont's FilmTec cleaning procedures say if output falls or salt passage rises, a pretreatment or pressure control malfunction, or increased recovery, should be considered first: the elements may not require cleaning. Once those are checked, DuPont's procedures say to clean FilmTec elements when normalised permeate flow drops 10%, normalised salt passage increases 5 to 10%, or normalised pressure drop increases 10 to 15%, and that if you wait too long, cleaning may not restore performance. DuPont's FilmTec technical manual says cleaning cannot be successful when a membrane is damaged, or heavily fouled or scaled (typically below 50% of specified flow in its standard element test), and that oxidation-damaged elements must be replaced. For your own element, see its maker's documents.

Why is TDS high after fitting a new membrane?

DuPont's FilmTec SW30 data sheet says SW30 elements generally reach stabilised salt rejection within 24 to 48 hours of continuous use, depending on feedwater characteristics and operating conditions. DuPont's SW30 and BW30 PRO-4040 and PRO-2540 data sheets say to discard the first hour's permeate. For first use, Vontron's SW11-2540 and ULP21-4040 sheets recommend flushing 15 to 25 minutes at low pressure, then 60 to 90 minutes at high pressure at no less than 50% of system design flow, and discharging all first-hour permeate and concentrate. For FilmTec elements in multi-element pressure vessels, DuPont's FilmTec technical manual names leaking O-rings as one cause of high solute passage at normal permeate flow. For your own element, check its maker's start-up steps.

How do you pickle (preserve) an RO membrane during a shutdown?

DuPont's FilmTec technical manual says FilmTec elements left in the pressure vessels of an RO or NF plant must be preserved any time the plant is shut down for more than 48 h, to prevent biological growth. DuPont's manual says in almost all cases the membranes must be cleaned first, with preservation within the next 10 h. DuPont's manual then says to totally immerse the elements in 1 to 1.5% sodium metabisulfite, venting the air, and to close all valves. DuPont's manual says to check the pH weekly, change the solution at pH 3 or lower and at least monthly, and keep the plant frost-free and no warmer than 45°C. For your own element, follow its maker's preservation procedure.

How do you store a spare RO membrane?

DuPont's FilmTec handling, preservation and storage excerpt says to keep new FilmTec elements in their original packaging, in a cool building or warehouse out of direct sunlight, between -4°C and +35°C. DuPont's excerpt says wet elements are preserved in buffered 1 wt% food-grade sodium metabisulfite and should be inspected for biological growth 12 months after shipment, then every three months; if the solution is not clear, soak the element in fresh solution and repack it. DuPont's excerpt says dry FilmTec elements need no preservation solution but should stay in their sealed bag until used, and that elements that dry out after use may irreversibly lose water permeability. For your own element, check its maker's storage guidance.