LG RO Membrane BW 4040 ES

Regular price $419.00
Sale price $419.00 Regular price $460.00
Unit price
Tax included.
Compare Ask a question

Ask a Question

* Required fields

Size guide Share
  • Estimated Delivery:Oct 19 - Oct 23

  • Next Day Dispatch

LG RO Membrane BW 4040 ES

LG RO Membrane BW 4040 ES

Regular price $419.00
Sale price $419.00 Regular price $460.00
Unit price
Industrial reverse osmosis

Bulk Pricing Available

Get exclusive discounts on high-volume orders.

In Stock & Ready To Ship

Fast dispatch for minimal downtime.

Technical Support & Assistance

Expert guidance & Support available.

Product Information

LG Reverse Osmosis Membrane, BW 4040 ES Element, 

  • 4”x40” Low Pressure Brackish Water Membrane.
  • 2500 gpd / 99.5% / 150 PSI.
  • high permeability at low feed pressure.
  • Suitable for low to medium salinity brackish water.
  • FREE Delivery (regional areas excluded)*

LG BW 4040 ES Energy Saving Brackish Water RO membranes offer high permeability at low feed pressure significantly reducing operating costs; suitable for low to medium salinity brackish water applications.

It operates at Low Pressure (10.3 bar / 150 PSI) inlet feed water pressure.

LG BW 4040 ES Enery Saving BWRO membranes offer a combination of high rejection, high flow, low pressure feed water, reliability and durability,

LG Chem’s NanoH2O™ brackish water RO membranes serve various municipal and industrial applications and major utilities around the world. LG BWRO membranes, all incorporated with innovative Thin Film Nanocomposite (TFN) technology, are offered in industry standard configurations and can easily fit into existing and new RO plants.   

All LG BWRO membranes provide superior performance along with intrinsic anti-fouling property and are suitable for applications where consistent and reliable performance is a must.     

Product Specifications:

Stabilized Salt Rejection: 99.5%*
Minimum Salt Rejection: 99.2%
Permeate Flow: 2500 gpd (9.5 m³/day)*
Membrane Area: 85 ft².
Diameter / Length: 4 inch / 40 inch.
*Test conditions: 2000 mg/l NaCl, 10.3 bar (150 psi), 25 °C (77 °F), pH 7, recovery rate 15%.
*Pre-treatment must be used to protect the membrane (softener, antiscalant dosing pump, sand filter, carbon filter, 5 mic cartridge fitler ...etc).   

Compatible with reverse osmosis membrane types:*

LG BW 4040 ES Membrane Element can be used as a replacement for the below membrane elements in your existing water treatment equipment.
FilmTec LC LE-4040 / Filmtec BW LE-4040 / GE Desal 4040 / Hydranautics ESPA2-LD-4040 / Toray TMG10D / CSM RE4040-BLN / Axeon HF1-4040.
*Check the data sheet for each membrane.   

Operation Conditions:

Max. working pressure:  600 psi (4.14MPa)
Max. Feed water flow:  16 gpm (3.6 m3/h)
Max. Temperature of Feed water:  45℃
Max. Feed water SDI (15 mins):  5.
Max. Feed Water Total Hardness: 10 ppm (softener or antiscalant should be used).
pH Range of Feed water during Continuous Operation:  2~11
pH Range of Feed Water during Chemical Cleaning:  2~12
Residual chlorine Concentration of feed water <0.1ppm Max.
Pressure drop of single membrane element:  15psi (0.1MPa)     

Commercial Application:

- Drinking water.
- Softened water for homes, hotels, commercial laundries and car wash.
- Spot free rinse for window cleaning and solar panel cleaning
- Pure water for pharmaceuticals, laboratories, Hemodialysis and electronics
- Sterilisers and autoclaves.
- Chemical industry.
- Aquarium water treatment.
- Boiler and cooling towers make-up water.
- Pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production. 

Manufactured by: LG Chem, Korea. (assembled in china).

Download:
Technical Data Sheet 

 

Discover more in our FAQ

What types of industrial water treatment products do you offer?

How do I know which product is right for my application?

Do you offer bulk pricing for large industrial orders?

How long does shipping take?

What is your return policy?

What happens if I receive a damaged or incorrect item?

How long does shipping take?

Do you ship internationally?

Recently Viewed Products

FilmTec XLE PRO 4040 Membrane, 4 inch x 40 inch Reverse Osmosis Membrane

  • Extra Low Energy Tape-Wrapped Membrane.
  • High flux (productivity) results in high yields.
  • Flow 2,750 gpd / Salt Rej 99% / Pressure 125 PSI.

FilmTec™ XLE PRO-4040 Elements offer better system performance and economics for small commercial systems by operating at very low applied pressure.

FilmTec XLE PRO-4040 elements are tape-wrapped. In addition to high-quality water and low energy costs, FilmTec membranes also deliver savings by providing long lasting and reliable performance. For added convenience, the elements are available in a dry state for rapid start-up.

High productivity membrane, it produces good water quality at very low applied pressure for drinking water and commercial applications.

Replaces Filmtec XLE-4040 (old version).

 

Specified Performance*:

Manufacturer Part Number: 12082995
Model Number: XLE PRO 4040
Permeate Flow: 2,750 gpd (10.4 m3 /d).
Stabilised Salt Rejection: 99%.
Nominal Active Surface Area: 87 ft².
Diameter: 4" (99mm)
Length: 40" (1016mm)
Membrane Type: Polyamide Thin-Film Composite. 

*1. Permeate flow and salt rejection based on the following test conditions: 2,000 ppm NaCl and 125psig (8.7 bar) , pH8, 77°F (25°C) and 15% recovery.
2. Minimum salt rejectionis 97%.
3. Permeate flows for individual elements may vary +/-15%.

XLE 4040 Specifications

Max. Feed Flow Rate: 3.2m³/hr
Max. Operating Pressure: 41bar
Max. Operating Temperature: 45°C
Max. Pressure Drop: 0.9 bar
pH. Range (Continuous Cleaning): 2 - 11
pH. Range (Short-Term Cleaning): 1 - 13
Maximum Feed Silt Density Index: SDI 5
Free Chlorine Tolerance: <0.1ppm
Manufactured by DuPont

 

 

DuPont RO Membranes

FilmTec™ Brackish Water Reverse Osmosis 4" Elements can separate salts from water and are produced with an automated fabrication process that ensures precision, consistency, and reliability. They are ideal for use in medium-sized water treatment system that produce less than approximately 10 gpm (2300 L/h) of permeate. DuPont Reverse Osmosis membranes build on a tradition of leadership in the thin-film composite membrane industry and meet the challenges of higher rejection in lower-pressure operations.

Commercial Application:

- Demineralisation for industrial applications, such as: PowerGeneration, Steel & Metal, Chemical & Petrochemical
- Drinking water.
- Softened water for homes, hotels, commercial laundries and car wash.
- Spot free rinse for window cleaning and solar panel cleaning
- Pure water for pharmaceuticals, laboratories, Hemodialysis and electronics
- Sterilisers and autoclaves.
- Chemical industry.
- Aquarium water treatment.
- Boiler and cooling towers make-up water.
- Pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production.

 

Download:
Filmtec XLE PRO-4040 Data Sheet

General Information:
- Keep elements moist at all times after initial wetting.
For successful operation of Reverse Osmosis (RO) and Nanofiltration (NF) membrane systems, the operation must follow the guidelines provided in the FilmTec™ ReverseOsmosis / Nanofiltration Elements Operation Excellence and Limiting Conditions Tech Fact (Form No. 45-D04388-en).
- To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.
- The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.
- Avoid static permeate-side back pressure at all times.
- Permeate obtained from the first hour of operation should be discarded.
- The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system.

Important Information:
- Proper start-up of reverse osmosis water treatment systems isessential to prepare the membranes for operating service  and to prevent membrane damage due to over feeding or hydraulic shock. Following the proper start-up sequence also  helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved..
- Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.

Product tabs

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Example Product Title

$19.99

Collapsible tab heading

Collapsible tab heading

Product bundles

Product bundles